Digital indicator M2 melt pressure strain gauges

Digital panel meter for metering of signals via strain gauges.

Item description

The M2-1MR5B.020X.570CD is a 5-digit meter for power / weight measuring via strain gauges with switching contact of 80% alignment and visual limit value monitoring via the display. Configuration happens via 4 front keys or via an optional PC-software. For further evaluations two switching points are optional available. Selectable software functions, a direct limit value adjustment in operating mode and the compact installation depth of 89mm create a solid device concept.

Digital indicator M3 melt pressure strain gauges

Digital indicators in LED-technique, available in different installation dimensions.

Item description

The M3-1MR5B.020X.S70BD is a 5-digit meter for measuring power / weight via strain gauges with switching contact for 80% alignment and a visual limit value monitoring via the display. The configuration happens via four front keys or via an optional PC-software. Optional two analog outputs, interfaces RS232/RS485 and up to 8 switching points are available. Select- able software functions and a direct limit value adjustment in operating mode complete the modern device concept.

Panel meter PM5 melt pressure strain gauges

Strain gauge mass pressure metering

Item description

The PM5.020X.1S70D with 4-wire-system and additional calibration contact for the 80%- alignment, is designed for sensor sizes which are based on strain gauges. The latter must not necessarily be used, as the device is suitable for any other strain gauge measuring. Therefor the device provides a regulated 10V-bridge supply. The 5-digit display shows the measure- ments, respectively the scaled value of the measured variable. Optionally available are 4 changeover relays for the monitoring of limit values, interfaces RS232/RS485 for data trans- fer to/from the device and analog outputs 0-10VDC, 4-20mA or 0-20mA for further evaluation.

Technical Data

Housing 96 x 48 mm
Display 5-digit
14 mm digit height
Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input DMS / Melt pressure: 1 mV/V, 2 mV/V, 3.3 mV/V free up to 4 mV/V
with 80% calibration
Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output -
Switch point 2 relays (change-over contact)
250 V / 5 AAC, 30 V / 5 ADC
Interface -
Power supply 230 VAC
10-30 VDC galvanic isolated
Other voltage supplies on demand!
Sensor supply Feeding 10 VDC / 20-40 mA / 250-500 Ohm
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • zero-key for triggering of Hold, Tara or setpoint setting
  • standard digital input for triggering of Hold, Tara or setpoint setting
  • flexible alarm system with adjustable delay times
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Downloads Data sheet and price list
Manual
Housing 96 x 48 mm
Display 5-digit
14 mm digit height
Colour: red, green, orange or blue display
Range displayed -19999 to 99999
Operation front panel keyboard protection class IP65
Input DMS / Melt pressure: 1 mV/V, 2 mV/V, 3.3 mV/V free up to 4 mV/V
with 80% calibration
Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 2 analog outputs
0/4-20 mA / 0-10 VDC / 16 Bit
Switch point 2 or 4 relays (change-over contacts)
250 V / 5 AAC, 30 V / 5 ADC
or 8 PhotoMos outputs (NOC) 30 V / 0.4 A AC/DC
Interface RS232 or RS485 galvanic isolated
Alternatively to analog output 2
Power supply 100-240 VAC 50/60 Hz / DC +/- 10%
10-40 VDC / 18-30 VAC 50/60Hz
Sensor supply Feeding 10 VDC / 20-40 mA / 250-500 Ohm
Software properties
  • min/max-memory with adjustable permanent display
  • 30 additional adjustable supporting points
  • display flashing at threshold value exceedance/undercut
  • zero-key for triggering of Hold, Tara or setpoint setting
  • standard digital input for triggering of Hold, Tara or setpoint setting
  • flexible alarm system with adjustable delay times
  • mathematical functions like reciprocal value, square root, squaring and rounding
  • sliding averaging
  • brightness control via parameter or front keys
  • programming interlock via access code
Downloads Data sheet and price list
Manual
Housing 96 x 48 mm
Display 5-digit
14 mm digit height
Colour: red
Range displayed -9999...99999
Operation front panel keyboard protection class IP65
Input Strain gauge / Melt pressure: 1 mV/V, 2 mV/V, 3.3 mV/V frei bis 6 mV/V
with 80% calibration
Digital input: <2.4V OFF, >10V ON, max. 30 VDC
Analogue Output 0-20 mA Burden ≤500Ohm 12Bit
4-20 mA Burden ≤500Ohm 12Bit
0-10 VDC Burden ≥100kOhm 12Bit
Switch point 2 or 4 relays (change-over contacts)
250 V / 5 AAC, 30 V / 5 ADC
Interface RS232 or RS485 galvanic isolated
Power supply 100-240 VAC 50/60 Hz / DC +/- 10%
10-40 VDC / 18-30 VAC 50/60Hz
Sensor supply Bridge supply 10 VDC / 20-50 mA / 200-500 Ohm
Software properties
  • integrated factory calibration for preset weighing cells
  • auto sensor recognition for 1mV/V-, 2mV/V- or 3.3mV/V-sensors
  • free selectable scaling and decimal point adjustment
  • alignment of a sensor with up to 30 additional supporting points
  • taring function for manual and automated triggering
  • fully automated or semi-automatic functions
  • min/max-memory with adjustable permanent display
  • display flashing at threshold value exceedance/undercut
  • flexible alarm system with adjustable delay time
  • programming interlock via access code
Downloads Data sheet and price list