MS-KW1 Resistance thermometer
Item description
- Accuracy: class A / class B / B1/2 DIN, B1/3 DIN, B1/10 DIN
- Conduit material: stainless steel 1.4571
- Protection class: IP65 (to 250°C) - this goes not for braid!
- Insulation resistance: test voltage 500 VDC
Max. temperature application area:
- Sensor: -200°C...450°C
- Conduit: stainless steel 1.4571 (316Ti) to 600°C
- Connection cable: PVC: -10°C...105°C / Silicon: -45°C...180°C / PTFE: -75°C...205°C / Glass fibre/braid: -60°C...550C
MSTL-L Temperature Limit Switch
Item description
- Sensor tube length up to 1000 mm
- Housing and cover PBT GF30, lens PMMA, process connection stainless steel 1.4571
- Protection class IP65 at least, electronics completely potted
- 8 electrical connection types are possible
- Process connection 1/4", 3/8", 1/2", 3/4", 1", 1/4 NPT, 3/8 NPT, 1/2 NPT
MSTS-WS Temperature Sensor
Item description
- Sensor tube length up to 1000 mm
- Display unit PC, housing PBT GF30, process connection stainless steel 1.4571
- Protection class IP65 at least, electronics completely potted
- 8 electrical connection types are possible
- Process connection 1/4", 3/8", 1/2", 3/4", 1", 1/4 NPT, 3/8 NPT, 1/2 NPT
MSTS-WT Temperature Transmitter
Item description
- Sensor tube length up to 1000 mm
- Housing and Cover PBT GF30, process connection stainless steel 1.4571
- Protection class IP65 at least, electronics completely potted
- 8 electrical connection types are possible
- Process connection 1/4", 3/8", 1/2", 3/4", 1", 1/4 NPT, 3/8 NPT, 1/2 NPT
Technical Data
Housing | Pt100 / RTD |
Input | Pt100 / Pt1000 / 2x Pt100 / 2x Pt1000 2-/3-/4-wire |
Downloads | Data sheet and price list |
Housing | Pt100 / RTD |
Display | LED red for switching status signal |
Input | Pt100 2-/3-wire |
Analogue Output | 4...20 mA 2-wire |
Switch point | 1 open Collector (max. 200 mA) |
Interface | HART-modem optional |
Power supply | 12-40 VDC |
Software properties | HART-protocol |
Downloads | Data sheet and price list |
Housing | Pt100 / RTD |
Display | 4-digit display, adjustable via 3 keys |
Input | RTD (Pt100) |
Analogue Output | 4...20 mA 2-wire |
Switch point | Configuration via HART-interface/software 2 open collector outputs |
Interface | HART-modem optional |
Power supply | 12-40 VDC |
Software properties | HART-protocol |
Downloads | Data sheet and price list |
Housing | Pt100 / RTD |
Input | RTD (Pt100) |
Analogue Output | 4...20 mA 2-wire |
Switch point | Configuration via HART-interface/software |
Interface | HART-modem optional |
Power supply | 12-40 VDC |
Software properties | HART-protocol |
Downloads | Data sheet and price list |