Montwill GmbH EN Panel meter Direct voltage / current (High voltage) 96 x 48 mm
Technical Data
Housing |
96 x 48 mm |
Display |
5-digit
14 mm digit height
Colour: red, green, orange or blue display |
Range displayed |
-19999 to 99999 |
Operation |
front panel keyboard protection class IP65 |
Input |
High voltages
0…1 ADC / span -1…1 ADC
0…50 VDC / span -50…50 VDC
0…300 VDC / span -300…300 VDC
0…600 VDC / span -600…600 VDC
Digital input: <2.4V OFF, >10V ON, max. 30 VDC |
Analogue Output |
0/4-20 mA / 0-10 VDC / 16 Bit
Alternatively digital input |
Switch point |
2 relays (change-over contact)
250 V / 5 AAC, 30 V / 5 ADC |
Interface |
– |
Power supply |
230 VAC |
Sensor supply |
– |
Software properties |
- min/max-memory with adjustable permanent display
- 30 additional adjustable supporting points
- display flashing at threshold value exceedance/undercut
- zero-key for triggering of Hold, Tara, display change, setpoint setting, alarm actuator
- flexible alarm system with adjustable delay times
- volume metering (Totalisator)
- mathematical functions like reciprocal value, square root, squaring and rounding
- constant setting/setpoint setting
- sliding averaging
- brightness control via parameter or front keys
- programming interlock via access code
|
Downloads |
Data sheet and price list |
Housing |
96 x 48 mm |
Display |
5-digit
14 mm digit height
Colour: red, green, orange or blue display |
Range displayed |
-19999 to 99999 |
Operation |
front panel keyboard protection class IP65 |
Input |
High voltages
0…1 ADC / span -1…1 ADC
0…50 VDC / span -50…50 VDC
0…300 VDC / span -300…300 VDC
0…600 VDC / span -600…600 VDC
Digital input: <2.4V OFF, >10V ON, max. 30 VDC |
Analogue Output |
2 analog outputs
0/4-20 mA / 0-10 VDC / 16 Bit |
Switch point |
2 or 4 relays (change-over contacts)
250 V / 5 AAC, 30 V / 5 ADC
or 8 PhotoMos outputs (NOC) 30 V / 0.4 A AC/DC |
Interface |
RS232 or RS485 galvanic isolated
Alternatively to analog output 2 |
Power supply |
100-240 VAC 50/60 Hz / DC +/- 10% |
Sensor supply |
– |
Software properties |
- min/max-memory with adjustable permanent display
- 30 additional adjustable supporting points
- display flashing at threshold value exceedance/undercut
- zero-key for the triggering of Hold, Tara, display change, setpoint setting, alarm actuator
- flexible alarm system with adjustable delay times
- volume metering (Totaliser)
- mathematical functions like reciprocal value, square root, squaring and rounding
- constant setting/setpoint setting
- sliding averaging
- brightness control via parameter or front keys
- programming interlock via access code
|
Downloads |
Data sheet and price list |