Montwill GmbH EN Tricolour (red-green-orange) Frequency 96 x 48 mm
Technical Data
Housing |
96 x 48 mm |
Display |
5-digit 14 mm digit height Colour: red, green, orange switchable by off-limit condition |
Range displayed |
0 to 99999 |
Operation |
front panel keyboard protection class IP65 |
Input |
Frequency 0,01 Hz to 999,99 kHz 3-wire PNP/NPN, Namur, incremental encoder, TTL signals Digital input: <2.4V OFF, >10V ON, max. 30 VDC |
Analogue Output |
0/4-20 mA / 0-10 VDC / 16 Bit Alternatively sensor supply and digital input |
Switch point |
2 relays (change-over contact) 250 V / 5 AAC, 30 V / 5 ADC |
Interface |
– |
Power supply |
230 VAC 10-30 VDC galvanic isolated Other voltage supplies on demand! |
Sensor supply |
10 VDC / 20 mA, incl. digital input 24 VDC / 50 mA, incl. digital input 24 VDC / 50 mA, incl. digital input & impulse output, max. 10kHz Alternatively analog output |
Software properties |
- min/max-memory with adjustable permanent display
- 30 additional adjustable supporting points
- display flashing at threshold value exceedance/undercut
- Schmitt-Trigger-input
- digital frequency filter for contact bounce suppression and interference suppresion
- frequency filter with varying pulse-duty factor
- zero-key for triggering of Hold, Tara, display change, setpoint setting, alarm actuator
- flexible alarm system with adjustable delay times
- volume metering (Totalisator) pulse precisely for frequencies up to 1kHz
- mathematical functions like reciprocal value, square root, squaring and rounding
- constant setting/setpoint setting
- sliding averaging
- brightness control via parameter or front keys
- programming interlock via access code
|
Downloads |
Data sheet and price list Manual |
Housing |
96 x 48 mm |
Display |
5-digit 14 mm digit height Colour: red, green, orange switchable by off-limit condition |
Range displayed |
0 to 99999 |
Operation |
front panel keyboard protection class IP65 |
Input |
Frequency 0,01 Hz to 999,99 kHz 3-wire PNP/NPN, Namur, incremental encoder, TTL signals Digital input: <2.4V OFF, >10V ON, max. 30 VDC |
Analogue Output |
2 analog outputs 0/4-20 mA / 0-10 VDC / 16 Bit |
Switch point |
2 or 4 relays (change-over contacts) 250 V / 5 AAC, 30 V / 5 ADC or 8 PhotoMos outputs (NOC) 30 V / 0.4 A AC/DC |
Interface |
RS232 or RS485 galvanic isolated Alternatively to analog output 2 |
Power supply |
100-240 VAC 50/60 Hz / DC +/- 10% 10-40 VDC / 18-30 VAC 50/60Hz |
Sensor supply |
10 VDC / 20 mA, incl. digital input 24 VDC / 50 mA, incl. digital input 24 VDC / 50 mA, incl. digital input & impulse output, max. 10kHz |
Software properties |
- min/max-memory with adjustable permanent display
- 30 additional adjustable supporting points
- display flashing at threshold value exceedance/undercut
- Schmitt-Trigger-input
- digital frequency filter for contact bounce suppression and interference suppresion
- frequency filter with varying pulse-duty factor
- zero-key for triggering of Hold, Tara, display change, setpoint setting, alarm actuator
- flexible alarm system with adjustable delay times
- volume metering (Totalisator) pulse precisely for frequencies up to 1kHz
- mathematical functions like reciprocal value, square root, squaring and rounding
- constant setting/setpoint setting
- sliding averaging
- brightness control via parameter or front keys
- programming interlock via access code
|
Downloads |
Data sheet and price list |